Accessories & Replacement Parts

Regulators & Relief Valves


Regulators & Relief Valves

High-pressure and low-pressure regulators and relief valves for the heater fuel train.


Shutoff Valves & Thermocouples


Shutoff Valves & Thermocouples

Shutoff valves (sometimes called safety valves) and thermocouples for Catco heaters.


Temperature Control


Temperature Control

Steady Heat Controllers and thermostats to control the temperature of process streams and spaces.


Wall & Floor Mount Brackets


Wall & Floor Mount Brackets

Mounting brackets and carts for Catco heaters of all sizes.


Starting Cables


Starting Cables

Electrical starting cables (sometimes called pigtails) for Catco heaters.


Facegrills & Reflectors


Reflectors

Reflectors for space heating applications.


Other Accessories


Other Accessories

Gauges, filters, ball valves, and other accessories.


Regulators & Relief Valves



Part Number Image Description
50-005 50-010 V3 912-type fuel gas regulator; 1/4″ NPT; max inlet 50 psig, outlet range 3-7 inches w.c.; for use in natural gas fueled Catco heaters; Fisher or similar
50-035 50-035 V3 High-pressure regulator; brass; 1/4″ NPT; max inlet 5500 psig, outlet range 0-75 psig; three outlets; Victor Meco Type P or similar
50-040 50-040 V3 High-pressure regulator; brass; 1/4″ NPT; max inlet 5500 psig, outlet range 0-75 psig; two outlets; Fisher 1301 or similar
50-037 50-037 V3 High-pressure regulator; stainless-steel; 1/4″ NPT; max inlet 5500 psig, outlet range of 0-150 psig; three outlets; Belgas P37 or similar
30-058 30-058 V3 Relief valve; brass; 1/4″ NPT; relieves at 150 psig; Fisher H120 or similar
50-036 50-036 V3 High-pressure regulator; brass; 1/4″ NPT; max inlet 5500 psig, max outlet 550 psig; two outlets; T-handle; Victor Meco Type P600 or similar
50-000 50-000 V3 Low-pressure appliance regulator; 1/4″ NPT; max inlet 1/2 psig, outlet range 3-7 inches WC; for use in natural gas fueled Catco heaters; Maxitrol or similar
50-010 50-010 V3 912-type fuel gas regulator; 1/4″ NPT; max inlet 250 psig, outlet range 9.25-13 inches w.c.; for use in LPG fueled Catco heaters; Fisher or similar

Shutoff Valves & Thermocouples



Part Number Image Description
30-127 30-127 V3 Low temperature shutoff valve, sometimes called a “safety valve”, Baso H19 or similar, 1/4″ NPT; 1/2 psi max inlet
30-010 30-010 V3 Thermocouple for Catco heaters; 18″ lead
30-012 30-012 V3 Extra long thermocouple for Catco heaters; 72″ lead

Temperature Control



Part Number Image Description
40-075 steady heat control v3 Steady Heat Controller; for use with Catco Instrument Gas Heater; gas outlet temp 135°-140° F; 1/4″ NPT
40-076 steady heat control v3 Steady Heat Controller w/ retrofit kit; for use with Catco Instrument Gas Heater; includes SHC and required fittings
40-037-XXXX F40-037-XXXX V3 Thermostat for heaters from 1500 to 72,000 BTU/hr; 3/8” NPT; specify heater BTU rating when ordering.
30-030 Mini Ball Valve FXM Manual turndown valve; reduces BTU by 50% when engaged; specify heater BTU rating when ordering

Wall & Floor Mount Brackets



Part Number Image Description
10-010 10-010 v3 Wall mount bracket for 6×12, 6×24, 12×12, 12×24 heaters; stainless-steel
10-025 10-025 V3 Wall mount bracket for 12×36, 12×48, 12×60 heaters; stainless-steel
10-026 10-025 V3 Wall mount bracket for 18×36, 18×48, 18×60 heaters; stainless-steel
10-027 10-025 V3 Wall mount bracket for 24×24, 24×48, 24×60, 24×72 heaters; stainless-steel
10-069 10-069 V3 Floor mount bracket for 6×12, 6×24, 12×12, 12×24 heaters; stainless-steel.
10-100 10-069 V3 Floor mount bracket for 12×36, 12×48, 12×60 heaters; stainless-steel.
10-101 10-101 V3 Floor mount bracket for 18×36, 18×48, 18×60 heaters; stainless-steel.
10-102 10-101 V3 Floor mount bracket for 24×24, 24×48, 24×60, 24×72 heaters; stainless-steel.

Starting Cables



Part Number Image Description
20-020 20-020 V3 16’ cable; battery clips; 12 V start; 12 ga wire; for use with plain junction box
20-021 20-020 V3 16’ cable; battery clips; 12 V start; 12 ga wire; for use with EP junction box
20-023 20-023 V3 16’ cable; three-prong plug; 120 V start; 12 ga wire; for use with EP junction box
20-030 20-023 V3 30’ cable; battery clips; 12 V start; 12 ga wire; for use with plain junction box
20-031 20-031 v3 30’ cable; battery clips; 12 V start; 12 ga wire; for use with EP junction box
20-026 20-032 V3 2’ cable; Crouse-Hinds or Appleton explosion-proof male plug; 12 V start; 12 ga wire; for use with EP junction box
20-032 20-032 V3 2’ cable; Crouse-Hinds or Appleton explosion-proof male plug; 120 V start; 12 ga wire; for use with EP junction box

Reflectors



Part Number Image Description
61-003 61-003 V3 Face-mounted reflector designed for a 6×12 heater
61-021 61-021 V3 Face-mounted reflector designed for a 12×12 heater
61-020 61-020 V3 Face-mounted reflector designed for a 6×24 heater
61-022 61-021 V3 Face-mounted reflector designed for a 12×24 heater
61-023 12x36 reflectors Face-mounted reflector designed for a 12×36 heater
61-025 12x36 reflectors Face-mounted reflector designed for a 12×48 heater
61-012 12x36 reflectors Face-mounted reflector designed for a 12×60 heater
61-024 12x36 reflectors Face-mounted reflector designed for a 18x36heater
61-027 18x36 relector Face-mounted reflector designed for a 18×48 heater
61-028 18x36 relector Face-mounted reflector designed for a 18×60 heater
61-011 18x36 relector Face-mounted reflector designed for a 24×24 heater
61-030 24x24 reflector Face-mounted reflector designed for a 24×48 heater
61-031 24x24 reflector Face-mounted reflector designed for a 24×60 heater
61-032 24x24 reflector Face-mounted reflector designed for a 24×72 heater

Other Accessories



Part Number Image Description
30-003-XXXX 30-003-XXXX V3 Fuel conversion kit; includes alternate orifice and label; specify details when ordering
35-073 35-073 V3 Gauge; 0-15 inches w.c.; 1/4″ NPT; bottom mount
35-076 35-076 V3 Gauge; 0-15 inches w.c.; 1/4″ NPT; back mount
30-070 2000 Psi drip pot Drip pot; max inlet 2000 psig
30-071 6000 psi drip pot Drip pot; max inlet 6000 psig
30-090 30-090 V3 Fuel gas filter assembly; max inlet 150 psig; clear acryllic bowl
30-091 30-091 V3 Fuel gas filter assembly; max inlet 500 psig; aluminum bowl
30-032 Mini Ball Valve FXM Mini ball valve; 1/4″ NPT; M x F
30-039 30-039 V3 Mini ball valve; 1/4″ NPT; F x F



Eliminate Downtime with Catco

As the go-to partner for energy resilience, we provide the simplest, safest way to prevent natural gas failures. Avoid costly problems such as freezing and hydrate formation by contacting us today.

©2024 Catco. All rights reserved.