1Measurements
2Review
3Submit

CUSTOM ENCLOSURE / MEASUREMENTS

Enclosure Measurements

Heaters(Required)
Hazardous Location Certified Heater configuration for single or dual heaters.

Enclosure drawing

Heater enclosure with labeled dimensionsA: LengthA · Length—B: HeightB · Height—C: WidthC · Width—D: Top to pipe centerD · Pipe offset—E: Pipe opening diameterE · Opening—F: Top-hole offsetF · Top-hole offset—G: Top openingG · Top opening—Representative enclosure · not to scale
A length · B height · C width · D top to pipe center · E pipe opening (Ø) · F top-hole center offset · ØG top opening diameter. Representative image; final fit is confirmed by Catco.

MEASUREMENT GUIDE

Understanding How to Measure Your Enclosure

Measure the full space your equipment needs, including flanges, bolts, nuts, and fittings. Allow extra room to access connections and fasteners.

Measurements are automatically rounded to the nearest ¼ inch for manufacturing.

Valve reference: A center to neck, B body length, C neck diameter, D top flange diameter

The valve reference has its own A–D key. Use the enclosure drawing’s A–G key when completing the form.

A · Length
Full length of the equipment, including flanges, bolts, studs, nuts, and connected fittings. Allow room to reach connections and fasteners.
C · Width
Enter your desired enclosure width. The heater will occupy some of the space inside. Our team will confirm the heater size and available room for your equipment.
B · Height
Height of the equipment portion inside; the neck can extend through the top.
G · Top opening
Neck diameter plus installation clearance.
F · Top position
Measure along A from the marked edge to the center of the top hole. When G is entered, F defaults to half of A, rounded to the nearest ¼ inch; halfway values round up. Enter a different F to override it. Select Use centered position to restore the default. Leave G and F blank if no top opening is needed.
E · Pipe size
Select the pipe size. Each option shows its opening diameter (Ø). Pipe openings use the listed diameters and are not rounded to the nearest ¼ inch. This choice does not resize the enclosure or change D.
D · Pipe position
Measure DOWN from the enclosure TOP to the pipe CENTER; D must not exceed B.
Please enter a number less than or equal to 24.
Internal length needed along A. Maximum: 24 inches.
Please enter a number less than or equal to 30.
Enter your desired enclosure width. The heater will occupy some of the space inside. Our team will confirm the heater size and available room for your equipment. Maximum width: 30 inches.
Please enter a number less than or equal to 30.
Internal height from bottom to top. Maximum: 30 inches.
Diameter of the circular top opening. Allow room for the valve neck and installation clearance. Supply G and F together, or leave both blank.
Measure along A from the marked edge to the center of the top hole. When G is entered, F defaults to half of A, rounded to the nearest ¼ inch; halfway values round up. Enter a different F to override it. Select Use centered position to restore the default. Leave G and F blank if no top opening is needed.
Select the pipe size. Each option shows its opening diameter (Ø). Pipe openings use the listed diameters and are not rounded to the nearest ¼ inch. This choice does not resize the enclosure or change D.
Measure DOWN from the TOP of the enclosure to the CENTER of the pipe. D must not exceed B (height).
Heater fit review

Enter your desired enclosure width. The heater will occupy some of the space inside. Our team will confirm the heater size and available room for your equipment.

Included With Your Enclosure

  • 1 × Hazardous Location Certified Heater
  • Explosion-proof junction box
  • Thermocouple
  • Low-temperature shutoff valve
  • Standard regulator
  • Standard pressure gauge
  • Standard hardware / accessories
Enter the manufacturer and model, if known. This helps us confirm the right fit.
Add a low-pressure regulator?
The standard regulator is included. A low-pressure regulator is a separate optional add-on; Catco will confirm its specification.

Additional Information

Choose the starting voltage for your heater.

Requested enclosure dimensions

— × — × —

Measurements are automatically rounded to the nearest ¼ inch for manufacturing.